Delta 591T0250 Installation Guide

Browse online or download Installation Guide for Sanitary ware Delta 591T0250. Delta 591T0250 Installation Guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Page 1
208360 Rev. C
591T__ 2 __ __
Write purchase model number here for future reference
PLEASE LEAVE this M&I Sheet with the owner, maintenance plumber, etc. as
items relating to ongoing maintenance suggestions and procedures are included.
NOTE: Control Box #0 and #1 are designed for routine
171°F (77°C) disinfection cycles up to 30 minutes.
Control Box #8 is not recommended for high temperature
disinfection cycles as the thermostatic mixing valve limits
the higher temperature flow output.
NOTE: For optimum performance of this product, we
recommend a system pressure between 20 and 80 PSI
static. This product will operate up to a maximum of 125
PSI static per ANSI and CSA requirements. However,
we do not recommend pressure above 80 PSI. Thermal
expansion or leaking pressure reducing valves may
require use of expansion tanks or relief valves to ensure
your system never exceeds its maximum intended
pressure setting.
060638A
Vandal Resistant Laminar Outlet
with Antimicrobial by Agion
®
1.5 GPM (5.7 L/min)
060640A
Vandal Resistant Flow Control
Aerator and Wrench
1.5 GPM (5.7 L/min)
061203A
Vandal Resistant Laminar
Outlet with Wrench
0.5 GPM (1.9 L/min)
061176A
Vandal Resistant Laminar
Outlet with Wrench
1.0 GPM (3.8 L/min)
061104A
Vandal Resistant Flow Control
Non-Aerating Spray Outlet
with Wrench
0.35 USGPM (1.3 L/min)
RP31704 - Optional
Vandal Resistant Spray
Outlet with Wrench
0.5 GPM (1.9 L/min)
060566A - Optional
Vandal Resistant Spray
Outlet with Wrench
1.0 GPM (3.8 L/min)
RP6001
Nut & Washer
060765A
Wrench
063211A
Spout Assembly
Fig. 1
RP30523
Braided Hose
063131A
3/8” x 3/8” Compression
Connector, Nut and Ferrule
063127A
Solenoid Valve
with 3/8”
Compression
Connectors
OPTION LIST
TRANSFORMERS
060704A
Transformer 110 to 24 VAC 20VA
up to 5 Electronic Valves
060771A
Transformer 110 to 24 VAC 40VA
up to 10 Electronic Valves
060772A
Transformer 110 to 24 VAC 100VA
up to 25 Electronic Valves
208360 208360 208360 208360 208360
208360 208360 208360 208360 208360
061031A
Deck Gasket (3/pkg)
Note: See page 3 for
parts breakdown on
recessed mount boxes.
www .specselect.com
060683A
24 VAC/6.4 VDC
Converter
061256A
36” Cable Extension
Accessories
060681A
Battery Holder
063128A
Battery Box Assembly less driver
board and battery holder
063131A
3/8” Comp Connect Nut
and Ferrile
060909A
Screen Assembly
060908A
Solenoid Holder
063127A
Solenoid Valve with 3/8”
Compression Connectors
061252A
Dual Driver Board
Masco H
2
Optics
& Proximity
060906A
Surface
Mount Housing
060905A
Cover Gasket
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - 591T__ 2 __ __

Page 1208360 Rev. C591T__ 2 __ __Write purchase model number here for future referencePLEASE LEAVE this M&I Sheet with the owner, maintenance pl

Page 2 - 208360 Rev. C

7" (178 mm)Max. 13" (331 mm) Max.Tie WrapsNOTE: Entire connection can beplaced inside battery box if desired.Fig. 2Page 2208360 Rev. CFOR

Page 3 - STEP 2. FAUCET INSTALLATION

Page 3208360 Rev. Cwww .specselect.comFOR RECESS MOUNT HOUSING: CONTROL BOXES #1 & 8 INSTALLATION AND SET UP INSTRUCTIONSInstallation should

Page 4 - STEP 6. SERVICES

WatertightConnectorFlexibleSensorCord ConduitSUPPLIED:3/8” MIP Outlet from Box3/8” Compression Joint at SpoutBALANCE BY OTHERS257mm (10.13")Contr

Page 5 - STEP 8. MAKING ADJUSTMENTS

Minimum RecommendedDistance 9” (229mm)Sensing Zone9” (228mm) default1"(25mm)Operation IllustrationPage 5208360 Rev. CFOR RECESS MOUNT HOUSING:

Page 6 - BATTERY STRENGTH INDICATOR

Page 6208360 Rev. Cwww .specselect.comSENSOR RANGE (d)The sensor range is the maximum distance at which the user is detected. The sensor range sett

Page 7 - CARE INSTRUCTIONS

Page 7208360 Rev. CTROUBLESHOOTING GUIDECheck to ensure faucet was installedaccording to the M&I sheet.Test for operation. If unit does notoper

Page 8

Delta Commercial Faucet Limited WarrantyGarantía Limitada de las Llaves de Agua Comerciales DeltaGarantie Limitée Delta CommercialAll parts of the Del

Comments to this Manuals