DELTA ELEKTRONIKA BV SM1500
Page 1 - 2 SPECIFICATIONS Rev. Sept. 2012
SM 15-100 SM 35-45 SM 52-30 SM 52-AR-60 SM 70-22 SM 120-13 SM 300-5 SM 400-AR-8
Out put
volt age
cur rent
AUTORANGING (2 ranges)
max. out put cur rent / volt age
0 - 15 V
0 - 100 A
no
-
0 - 35 V
0 - 45 A
no
-
0 - 52 V
0 - 30 A
no
-
0 - 52 V
0 - 60 A
yes
60 A / 0-26 V
30 A / 26-52 V
0 - 70 V
0 - 22 A
no
-
0 - 120 V
0 - 13 A
no
-
0 - 300 V
0 - 5 A
no
-
0 - 400 V
0 - 8 A
yes
8 A / 0-200 V
4 A / 200-400 V
In put
AC sin gle phase, 48 - 62 Hz
rated volt age range
rated fre quency
Power De rat ing vs in put:
90 V : P
out max
(W), I
in
(A)
100 V : P
out max
(W), I
in
(A)
110 V : P
out max
(W), I
in
(A)
230 V : P
out max
(W), I
in
(A)
power fac tor, 100%, 50% load
in ter nal fuses
standby in put power (V
o
=I
o
=0)
standby in put power (V
o
=V
max
)
90 - 265 V
100 - 240 V
50 / 60 Hz
1170,16
1317, 16
1492, 16
1500, 7.5
0.99, 0.98
25 AT
12 W
22 W
90 - 265 V
100 - 240 V
50 / 60 Hz
1185, 16
1334, 16
1498, 16
1575, 7.7
0.99, 0.98
25 AT
12 W
22 W
90 - 265 V
100 - 240 V
50 / 60 Hz
1200,16
1350,16
1505,16
1560, 7.7
0.99, 0.98
25 AT
12 W
22 W
90 - 265 V
100 - 240 V
50 / 60 Hz
1200,16
1350,16
1505,16
1560,7.7
0.99, 0.98
25 AT
12 W
22 W
90 - 265 V
100 - 240 V
50 / 60 Hz
1200,16
1350,16
1505,16
1540, 7.6
0.99, 0.98
25 AT
12 W
22 W
90 - 265 V
100 - 240 V
50 / 60 Hz
1200,16
1350,16
1505,16
1560, 7.7
0.99, 0.98
25 AT
12 W
22 W
90 - 265 V
100 - 240 V
50 / 60 Hz
1200,16
1350,16
1500,16
1500, 7.4
0.99, 0.98
25 AT
12 W
22 W
90 - 265 V
100 - 240 V
50 / 60 Hz
1200,16
1350,16
1505,16
1600, 7.8
0.99, 0.98
25 AT
12 W
25 W
26 V / 52 V 200 V / 400 V
Ef fi ciency
AC 230 V in put, full load
AC 115 V in put, max. load
87 %
83 %
90 %
86 %
90 %
86 %
89 / 90 %
84%
90 %
86 %
90 %
86 %
91 %
86 %
90 / 91%
86%
Reg u la tion
Load 0 - 100% CV
Line 120 - 265 V AC CV
(mea sured on sense block)
0.5 mV
0.2 mV
1 mV
0.5 mV
2 mV
0.7 mV
2 mV
0.7 mV
2.5 mV
1 mV
4 mV
2 mV
10 mV
3 mV
12 mV
4 mV
Load 0 - 100% CC
Line 120 - 265 V AC CC
(in ter nal volt age sense)
5 mA
1 mA
3 mA
0.5 mA
1.5 mA
0.5 mA
2 mA
1 mA
1 mA
0.25 mA
0.6 mA
0.2 mA
0.5 mA
0.1 mA
0.5 mA
0.2 mA
Rip ple + noise
rms (BW=300 kHz) CV
p-p (BW=20 MHz) CV
rms (BW=300 kHz) CC
p-p (BW=20 MHz) CC
CC-rip ple at full load
2 mV
8 mV
15 mA
80 mA
1.8 mV
8 mV
5 mA
15 mA
2 mV
15 mV
3 mA
10 mA
2 mV
15 mV
10 / 3 mA
30 / 10 mA
3 mV
15 mV
3 mA
10 mA
7 mV
30 mV
2 mA
6 mA
7 mV
50 mV
0.5 mA
4 mA
15 mV
80 mV
1.2 / 0.6 mA
6 / 3 mA
Temp. coeff., per °C CV
CC
35.10
-6
60.10
-6
Sta bil ity
af ter 1 hr warm-up
dur ing 8 hrs CV
CC
t
amb
= 25 ± 1 °C, V
in
= 230 V AC
(int. volt age sens ing for CC-stab.)
6.10
-5
9.10
-5
An a log Pro gram ming
CV CC
Pro gram ming in puts
in put range
ac cu racy
off set
temp. coeff. off set
in put im ped ance
0 - 5 V
± 0.2%
- 0.1 ... +1.3 mV (on 5V)
10 µV / °C
> 1 MOhm
0 - 5 V
± 0.5%
0 ... +2.2 mV (on 5V)
50 µV / °C
> 1 MOhm
Mon i tor ing out put
out put range
ac cu racy
off set
temp. coeff. off set
out put im ped ance
0 - 5 V
± 0.2%
- 1... 0 mV (on 5V)
3 µV / °C
2 Ohm / max. 4 mA
0 - 5 V
± 0.5%
- 1.1... 0 mV (on 5V)
60 µV / °C
2 Ohm / max. 4 mA
Ref er ence volt age
on prog. con nec tor V
ref
TC
5.114 V ± 15 mV (Ro = 2 Ohm, max. 4 mA)
20 ppm
+12 V out put V
o
on prog. Con nec tor I
max
R
o
12 V ± 0.2 V
0.2 A
3 Ohm
Re lay Out puts
ACF
DCF
AC - Fail both NO and NC con tact
DC - Fail
1
) both NO and NC con tact
1
) out put volt age ± 5% be yond set point
Page view 1
1 2 3 4 5 6

Comments to this Manuals

No comments