USing acc-36E with power umac 31
Manual ADC Read Using ACC-36E Structures
Power PMAC supports the following structures for manually reading ACC-36E:
Structure
Description
ACC36E[n].ConvertCode
ADC pair and convert code select
ACC36E[n].ADCRdyLow
Ready-to-read bit for ADC#1 through #8
ACC36E[n].ADCRdyHigh
Ready-to-read bit for ADC#9 through #16
ACC36E[n].ADCuLow
Read ADC#1 through #8 as unipolar
ACC36E[n].ADCuHigh
Read ADC#9 through #16 as unipolar
ACC36E[n].ADCsLow
Read ADC#1 through #8 as bipolar
ACC36E[n].ADCsHigh
Read ADC#9 through #16 as bipolar
ACC36E[n].ADCHighLow
Read ADC pair as one word
Note
n is the index specified by the DIP switch SW1 setting of the
ACC-36E.
Setting up the manual ADC read with Power PMAC requires two simple steps:
1. Configure ACC36E[n].ConvertCode = (ADC Pair #) 1 for Unipolar Inputs
= (ADC Pair #) + 7 for Bipolar Inputs
ADC Pair #
ADC#
Channel Select Pointer Value
Unipolar Inputs
Bipolar Inputs
1
1 & 9
0
8
2
2 & 10
1
9
3
3 & 11
2
10
4
4 & 12
3
11
5
5 & 13
4
12
6
6 & 14
5
13
7
7 & 15
6
14
8
8 & 16
7
15
2. Read/copy ADC data results as soon as the ADC Ready Bits are “ready” (that is, their
values become 1). This can be achieved easily in a Power PMAC script PLC, and
implemented for all channels to be read consecutively and consistently, creating a
“custom automaticADC read function.