ACC-36E Manual
ACC-36E Layout & Pinouts 68
J1 Top: ADC1 through ADC4
J1 Top: D-sub DA-15F
Mating: D-sub DA-15M
2345
9101112
67
1314
8
15
1
Pin #
Symbol
Function
Description
1
ADC1+
Input
+Analog Input #1
2
ADC2+
Input
+Analog Input #2
3
ADC3+
Input
+Analog Input #3
4
ADC4+
Input
+Analog Input #4
5
Open
N/A
6
AGND
Common
Ground
7
+12V
Output
Positive supply
8
AGND-
Common
Ground
9
ADC1-
Input
-Analog Input #1
10
ADC2-
Input
-Analog Input #2
11
ADC3-
Input
-Analog Input #3
12
ADC4-
Input
-Analog Input #4
13
Open
N/A
14
AGND
Common
Ground
15
-12V
Output
Negative supply
Note
The ±12V output can be used for an external device (i.e. sensor).
The drawn current should not exceed 0.5 Amperes.
The common ground (pin #7) is tied to the digital ground of the
UMAC rack.
J2 Top: ADC5 through ADC8
J2 Top: D-sub DA-15F
Mating: D-sub DA-15M
2345
9101112
67
1314
8
15
1
Pin #
Symbol
Function
Description
1
+ADC5
Input
+Analog Input #5
2
+ADC6
Input
+Analog Input #6
3
+ADC7
Input
+Analog Input #7
4
+ADC8
Input
+Analog Input #8
5
Open
N/A
6
AGND
Common
Ground
7
+12V
Output
Positive supply
8
AGND
Common
Ground
9
-ADC5
Input
-Analog Input #5
10
-ADC6
Input
-Analog Input #6
11
-ADC7
Input
-Analog Input #7
12
-ADC8
Input
-Analog Input #8
13
Open
N/A
14
AGND
Common
Ground
15
-12V
Output
Negative supply
Note
The ±12V output can be used for an external device (i.e. sensor).
The drawn current should not exceed 0.5 Amperes.
The common ground (pin #7) is tied to the digital ground of the