SINGLE PHASE INSTALLATION
Fig. 12
A
B
Fig. 13 Fig. 14
1. Remove screw (A) Fig. 12, and terminal strip cover (B).
2. Remove plastic covering (C) Fig. 13, that snaps into
terminal strip.
3. Bring power line through access hole in bottom of
terminal strip box and connect the two power lines to
terminals (D) Fig. 14, and the green ground wire to ground
screw (E).
4. Replace plastic covering (C) Fig. 13, and terminal
strip cover removed in STEP 1.
C
E
D
IMPORTANT: The jointer cutterhead is a high inertia load which causes the motor to draw a high inrush
current during starting. The jointer must be connected to an electrical circuit protected by a properly sized
fuse or circuit breaker to handle this high inrush of current. We recommend either a 30 Amp time lag fuse, or
a 40 Amp motor start circuit breaker.
If your machine is supplied with single phase electricals, proceed as follows when connecting your machine to
an electrical power system: