SYSTEM SPECIFICATIONS*
FREQUENCY RANGE 403-430 MHz** & 450-512 MHz
BATTERY VOLTAGE 13.8 volts ±20% RX
13.6 or 13.4 volts ±20% TX
BATTERY DRAIN (Maximum)
Receive
Squelched 0.7 amperes
Unsquelched 2.2 amperes
Transmit
35/40 watts 10.0 amperes at 13.6 volts
30 watts (DOC***) 10.0 amperes at 13.6 volts
50 watts 12.0 amperes at 13.6 volts
80 watts 21.0 amperes at 13.4 volts
90 watts 22.0 amperes at 13.4 volts
100 watts 23.0 amperes at 13.4 volts
FREQUENCY STABILITY 0.0005% or optional 0.0002%
TEMPERATURE RANGE -30°C (-22°F) to +60°C (140°F)
DUTY CYCLE 100% Receive, 20% Transmit (EIA)
DIMENSION, LESS ACCESSORIES (H x W x D)
35-50 watts 65 mm x 260 mm x 325 mm
(2.5 x 10.2 x 12.7 inches)
80-100 watts 65 mm x 290 mm x 325 mm
(2.5 x 11.4 x 12.7 inches)
WEIGHT, LESS ACCESSORIES
35-50 watts 5.9 kg (12.9 pounds)
80-100 watts 6.5 kg (14 pounds)
* These specifications are intended primarily for the use of the serviceman. Refer to the appropriate
Specifications Sheet for the complete specifications.
** 403-430 MHz combinations are for International use (50 Watt Transmitters). 421-430 MHz
combinations may be used for domestic applications.
*** Canadian Department of Transportation.
MILITARY SPECIFICATIONS
STANDARD METHODS/PROCEDURES
MIL-STD-810-C MIL-STD-810-D
Low Pressure 500.1/Procedure 1 500.2/Procedure 1
High Temperature 501.1/Procedure 1,2 501.2/Procedure 1,2
Low Temperature 502.1/Procedure 1 502.2/Procedure 1,2
Temperature Shock 503.1/Procedure 1 503.2/Procedure 1
Solar Radiation 505.1/Procedure 1 505.2/Procedure 1
Humidity 507.1/Procedure 2 507.2/Procedure 2
Vibration 514.2/Procedure 8, 10 514.3/Procedure 1
Shock 516.2/Procedure 1,2,3,5 516.3/Procedure 1, 3, 4, 5, 6