Page view 1
7" (178 mm)
Max.
13" (331 mm) Max.
NOTE: Entire connection can be placed
inside battery box if desired.
Fig. 2
Tie Wraps
Page 2
208356 Rev. C
FOR SURFACE MOUNT HOUSING: CONTROL BOX #0
STEP 1. FAUCET INSTALLATION
STEP 2. BATTERY BOX INSTALLATION
Mount battery box to wall under sink using the 4 supplied screws and anchors. Use
1/4” drill for wall anchors. Be sure to install the box within the dimensions provided
so the hose and spout cable will reach connections at faucet and battery box.
Refer to illustration (Fig. 2).
STEP 3. FLUSH SYSTEM
To flush supply line, assemble these components as shown (Fig. 3) and run water for 1
minute. Shut off water supply. Attach aerator. NOTE: Do not connect supply to the
solenoid inlet until line is flushed directly out spout.
STEP 4. CONNECT WATER SUPPLY
Disassemble the components, reassemble the ones shown here (Fig. 4) supply line
and adaptor to the bottom fitting on box, braided hose to the top fitting on box. Use
plumber tape where indicated on adaptor. Turn on water supply. DO NOT SOLDER
CONNECTIONS!
STEP 5. POWER UP
Unscrew the battery box lid screws (2). Install 4 “Alkaline C” batteries in holder or snap
the battery clip directly to the optional 24 VAC converter.
BATTERY VERSION Install four “Alkaline C” batteries provided into the battery holder.
After the batteries are installed, make the sensor connection on the driver board neatly
inside the battery box. Connect battery clip to battery pack. Two beeps indicate product
is ready to use. Use caution not to damage wires or components on electronic driver
board. See Fig. 5. Secure lid using screws. Do not use 9V battery.
HARDWIRE VERSION Install CSA and/or UL approved Class 2 transformer or equiv-
alent in a convenient location or in a pipe chase. (Do NOT install the transformer
inside the control box.) With the power off, bring the 24 VAC supply wires to the box.
Connect the 24 VAC supply to the 060683A conversion kit. Connect the battery snap
of the hardwire converter to the driver board battery clip. Ensure snap does not touch
any conductive metal surface, then make the sensor connection on the control module
neatly inside the battery box. Turn on power supply for the transformer. Do not remove
battery snap from hardwire converter by using a flat screwdriver, damage may result.
STEP 6. PREPARE SINK AREA
Before connecting the spout cable – clean off counter and remove all objects
from the sink.
STEP 7. TIE SPOUT CABLE
Attach spout cable to box connector. Use tie wraps to secure spout cable to spout hose.
Your faucet is now ready for use (Fig. 2).
STEP 8. TEST FOR OPERATION
Test for operation. If faucet leaks from spout outlet: SHUT OFF WATER SUPPLIES.
Replace solenoid (2).
If faucet exhibits very low flow: A) Remove and clean spray outlet, or B) SHUT OFF
WATER SUPPLY. Clean or replace screen assembly (2). If unit does not work properly;
see Troubleshooting Guide on page 7.
INSTALLATION AND SET UP INSTRUCTIONS
Installation should be in accordance with local plumbing and electrical codes.
FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION.
3/8" O.D.
Copper
Inlet
Bypass
Adapter
Ferrule
Nut
Spout
Hose
Plumber
Tape
Fig. 3 Fig. 4
063131A
3/8” Comp
Connect Nut
and Ferrile
Connect 20” braided hose to spout inlet. Clean deck/sink surface where faucet will be
mounted. Mount faucet to sink using nut(s) and washer(s) provided. Installation of the
single hole deck gasket (060564A) between the turret base and mounting surface is the
recommended assembly practice. Ensure that gasket is sitting flat on the deck and the
turret is centered on the gasket. Use the same procedure for installation of optional 4”
or 8” deck plate package (060546A or 060547A). Mount the faucet to the sink using
nut(s) and washer(s) provided. Do not overtighten the nut (RP6087) or reposition the
turret once installed, otherwise damage to the gasket may result. Cutting or trimming
of the gasket is not recommended. NOTE: If the gasket is trimmed or not installed,
then use clear silicone sealant between the faucet and lavatory to prevent water
from leaking beneath lavatory.
www .specselect.com
Fig. 5
Trap
jacket of
cable in
hole for
strain
relief.
NOTE: Always make
sure driver board is in
place before inserting
the battery pack. Use
caution not to pinch
wires or damage
components on the
electronic driver board.