2. System Function
2-16 DVP-MC operating manual
Serial
No
Parameter Name Function Data Type
Default
Value
5
Software Limitation
Enable software limitation;
If it item is not selected, The maximum/
minimum position of axis which software
limits is invalid.
If selected, the maximum/
minimum position of axis limited by
software is valid.
BOOL 0
6 Maximum Position
The max. position of axis limited by
software
REAL -
7 Minimum Position
The mini. position of axis limited by
software
REAL -
8 Acceleration Type Trapezoid/Sinus - Trapezoid
Servo motor presents the features in process of acceleration and deceleration while DVP10MC11T is
controlling servo drive.
Trapezoid:
Sinus:
9 Unit Numerator
To set the pulse quantity needed when
motor rotates for one circle by adjusting
unit numerator and the denominator.
UINT 128
10 Unit Denominator
To set the pulse quantity needed when
motor rotates for one circle by adjusting
unit numerator and the denominator.
UINT 1
11 Increment
How many pulses are needed when servo
motor rotates for one circle.
UINT 10000
Adjusting the Unit Numerator and Unit Denominator parameters is to set the electronic gear proportion
of servo drive. Electronic gear proportion is to set how many pulses servo drive receives while servo
motor rotates for a circle.
The resolution of A2 servo drive motor is 1280000 pulses/ circle;
Suppose the value of parameter 11 is N, N* (Unit Numerator/ Unit Denominator)=1280000
Page view 23