Appendix C
C-14 DVP-MC operating manual
Special
D
Modbus
address
HEX
Function Range Type
Latche
d
Attribute
D26149 E625 -- No Read only
D26150 E626
Pulse number needed when servo
motor rotates for one circle.
--
DINT
No Read only
D26151 E627
The allowed error between the
given and feedback pulse number
-- UINT No Read only
D26155 E62B
Current torque (Rated torque
permillage)
-- INT No Read only
D26156 E62C -- No Read only
D26157 E62D
Current speed (Unit: 0.1 r/min
--
DINT
No Read only
D26158 E62E
Present current (Rated current
permillage)
-- INT No Read only
D26159 E62F -- No Read only
D26160 E630
Custom parameter value
--
DINT
No Read only
D26161 E631
D26162 E632
The phase of the terminal actuator
0~ modulo REAL
No Read only
D26163 E633
D26164 E634
The position of the terminal
actuator
-2147483648
~
2147483647
DINT
No Read only
Note: The axis parameters such as Position, Velocity, Torque, Current and User defines parameter
can be read via special D only when they are selected. For the method of selecting the
relevant parameter, see section 2.3.1.