OPERATING CONTROLS AND ADJUSTMENTS
Fig. 7
Fig. 8
INTERMEDIATE OPERATION – To turn the saw “ON”
depress switch trigger (A) Fig. 7. To turn the saw “OFF”
release switch trigger (A).
CONTINUOUS OPERATION – Depress switch trigger
(A) Fig. 8, and push in lock button (B). The saw will
remain “ON” until the switch trigger (A) is depressed.
LOCKING SWITCH IN
THE “OFF” POSITION
IMPORTANT: We suggest that when the machine is not
in use, the switch be locked in the “OFF” position using
a padlock (C) through the holes in the switch trigger (A),
as shown in Fig. 9.
A
A
B
A
TOTAL LENGTH OF GAGE OF EXTENSION
CORD IN FEET CORD TO USE
0 - 25 14 AWG
26 - 50 12 AWG
51 - 100 Not Recommended
101 - 150 Not Recommended
EXTENSION CORDS
Use proper extension cords. Make sure your extension
cord is in good condition and is a 3-wire extension cord
which has a 3-prong grounding type plug and a 3-hole
receptacle which will accept the tool’s plug When using
an extension cord, be sure to use one heavy enough to
carry the current of the saw. An undersized cord will
cause a drop in line voltage resulting in loss of power
and overheating. Fig. 6A shows the correct gage to use
de-pending on cord length. If in doubt, use the next
heavier gage. The smaller the gage number, the heavier
Fig. 6A
ON-OFF SWITCH
Your 14 Abrasive Cut-Off Saw is provided with an
ON-OFF switch that can be used for INTERMEDIATE
OPERATION or CONTINUOUS OPERATION, as follows:
Fig. 9