11
NOTE: Reverse the procedure to remove the column extension.
Fig. 20
A
B
C
OPERATING CONTROLS AND ADJUSTMENTS
The power switch is located on the left side of the mortiser.
To turn the mortiser “ON”, press the green start button (A)
Fig. 21. To stop the mortiser, push the red button (B).
When the tool is not in use, the switch should be locked in the
“OFF” position to prevent unauthorized use. Insert the
lockout pin (C) Fig. 22 (Delta accessory model number 50-
164) through the hole in the start button (A). Place the 1/8"
shank of a lock through the hole in the lockout pin and secure.
STARTING AND STOPPING MORTISER
LOCKING SWITCH IN THE “OFF” POSITION
A
B
C
A
A depth stop rod (A) Fig. 23 is provided to limit the depth of
the chisel. To adjust the depth stop rod (A), loosen the lever
(C) and lower the head until the chisel is at the desired depth.
Lower the depth stop rod (A) until it contacts the top of the
column (D) and tighten the lever (C).
DEPTH STOP ROD
A
D
C
The fence (A) Fig. 24can be moved in or out by loosening the
lock handles (B), and rotating the fence rack handle (C). Move
the fence to the desired position and tighten the handles (B).
NOTE: Levers (B) are spring-loaded and can be repositioned
by pulling out on the lever and repositioning it on the serrated
nut located underneath the lever.
FENCE
A
B
C
Fig. 21
Fig. 22
Fig. 23
Fig. 24
To prevent damage to the unit, place the rack
cover over the gear. This action will prevent
the cover from being trapped between the
rack and the gear.