EXTENSION CORDS
Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire
extension cord which has a 3-prong grounding type plug and matching receptacle which will accept the machine’s
plug. When using an extension cord, be sure to use one heavy enough to carry the current of the machine. An
undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Fig. D-1 or D-2, shows
the correct gauge to use depending on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge
number, the heavier the cord.
Fig. D-1
Fig. D-2
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere Total Length Gauge of
Rating Volts of Cord in Feet Extension Cord
0-6 120
up to
25 18 AWG
0-6 120 25-50 16 AWG
0-6 120 50-100 16 AWG
0-6 120 100-150 14 AWG
6-10 120
up to
25 18 AWG
6-10 120 25-50 16 AWG
6-10 120 50-100 14 AWG
6-10 120 100-150 12 AWG
10-12 120
up to
25 16 AWG
10-12 120 25-50 16 AWG
10-12 120 50-100 14 AWG
10-12 120 100-150 12 AWG
12-16 120
up to
25 14 AWG
12-16 120 25-50 12 AWG
12-16 120
GREATER THAN 50 FEET NOT RECOMMENDED
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere Total Length Gauge of
Rating Volts of Cord in Feet Extension Cord
0-6 240
up to
50 18 AWG
0-6 240 50-100 16 AWG
0-6 240 100-200 16 AWG
0-6 240 200-300 14 AWG
6-10 240
up to
50 18 AWG
6-10 240 50-100 16 AWG
6-10 240 100-200 14 AWG
6-10 240 200-300 12 AWG
10-12 240
up to
50 16 AWG
10-12 240 50-100 16 AWG
10-12 240 100-200 14 AWG
10-12 240 200-300 12 AWG
12-16 240
up to
50 14 AWG
12-16 240 50-100 12 AWG
12-16 240
GREATER THAN 100 FEET NOT RECOMMENDED
3. 240 VOLT SINGLE PHASE OPERATION
The motor supplied with your saw is a dual voltage,
120/240 volt motor. If it is desired to operate your
machine at 240 volts, single phase, it is necessary to
reconnect the motor leads in the motor junction box by
following the instructions given on the motor
nameplate.
MAKE SURE MOTOR IS
DISCONNECTED FROM POWER SOURCE BEFORE
RECONNECTING MOTOR LEADS.
It is also necessary to replace the 120 volt plug,
supplied with the motor, with a UL/CSA Listed plug
suitable for 240 volts and the rated current of your
machine as illustrated in Fig. C. Contact your local
Authorized Delta Service Center or qualified electrician
for proper procedures to install the plug. The machine
must comply with all local and national electrical codes
after the 240 volt plug is installed.
The machine with a 240 volt plug should only be
connected to an outlet having the same configuration
as the plug illustrated in Fig. C. No adapter is available
or should be used with the 240 Volt plug.
IN ALL CASES, MAKE CERTAIN THE
RECEPTACLE IN QUESTION IS PROPERLY
GROUNDED. IF YOU ARE NOT SURE HAVE A
QUALIFIED ELECTRICIAN CHECK THE
RECEPTACLE.
Fig. C
GROUNDED OUTLET BOX
CURRENT
CARRYING
PRONGS
GROUNDING BLADE
IS LONGEST OF THE 3 BLADES
4. Permanently connected machines:
If the machine is intended to be permanently connected, all
wiring must be done by a qualified electrician and conform
to the National Electric Code and all local codes and
ordinances.
* THREE PHASE OPERATION: Three phase machines
are not supplied with a power cord and must be
permanently connected to a building’s electrical
system. Extension cords can’t be used with a three
phase machine.
* LVC MAGNETIC MOTOR CONTROL: If you
purchased a machine that has a Low Voltage Magnetic
Motor Control System, refer to its instruction manual for
installation guidance.