204499 Rev. A
STEP 7b. CALIBRATION
After power is applied to the driver board, it generates an ascending beep tone
which prompts the installer to step away from the unit. During this process the
water will turn ON and OFF on its own as the unit undergoes calibration. Please
allow up to 30 seconds for the unit to calibrate itself to its new environment.
STEP 8. TEST FOR OPERATION
Test for operation. If OK, then close lid - Use caution not to damage wires or
components on electronic driver board. See Fig 6. Secure lid using screws.
If faucet leaks from spout outlet: SHUT OFF WATER SUPPLIES. Check proper
solenoid connection. Replace solenoid if problem persists. If faucet exhibits
very low flow: A) Remove and clean Spray Outlet or B) SHUT OFF WATER
SUPPLY. Clean or replace Screen Assembly (2). If unit does not work
properly, see Trouble Shooting Guide on page 5.
INSTALLATION AND SET UP INSTRUCTIONS
Installation should be in accordance with local plumbing and electrical codes.
FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION.
Fig. 5
Trap
jacket of
cable in
hole for
strain
relief.
2
NOTE: Always make
sure driver board is in
place before inserting
the battery pack. Use
caution not to pinch
wires or damage
components on the
electronic driver board.
1
Fig. 6
STEP 9. BASIC OPERATION AFTER CALIBRATION
Proximity™ sensing technology works by creating an electrical field around
a conductor (the spout) and monitoring the change in capacitance that
the conductor undergoes. The change in capacitance (the ability to store
an electrical charge) is brought on by a 2nd conductor (a human body)
entering the Proximity™ field. As the human hand enters and leaves the
vicinity of the electrical field around the spout, the solenoid is opened and
closed accordingly. It is critical in the installation process that all electrical
and mechanical connections be as tight and rigid as possible, ensuring a
smooth signal is carried from the driver board to the spout, and back again.
Upon calibration, test the function of the product by
placing your hands within close proximity of the
spout. The solenoid will open, then close once
hands are removed from the sensing zone.