Delta F-25 User Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
DELTA 10 F
1M
F
!
!
7
6- IMPORTANT SAFETY INFORMATION
6.1 Fire prevention:
-Never locate the fixture on any flammable surface.
-Minimum distance from flammable materials: 1 m.
-Minimum distance from the closest illuminable surface: 1 m.
-Replace any blown or damaged fuses only with those of identical value. Refer to the wiring diagram if
there is any doubt.
-Connect the projector to mains power via a thermal magnetic circuit breaker.
6.2 Prevention of electric shock:
-High voltage is present inside the unit. Isolate the projector from the mains supply prior to performing
any function which involves touching the inside of the unit.
-The level of technology inherent in the DELTA 10 F requires the assistance of specialised personnel for
all servicing.Please refer to an authorised D.T.S. service centre.
-A good earth connection is essential for proper functioning of the projector.
Never connect the unit without proper earth connection.
-The fixture should be located in places with a good air ventilation.
6.3 Protection against direct light radiation:
-Never turn the unit on if any of the lenses or the glass lenses protection is damaged.
-Never look directly the leds when they are on.
6.4 Safety:
-The projector should always be installed with bolts, clamps and other tools that are capable of
supporting the weight of the unit.
-Always use a second safety chain to sustain the weight of the unit in case of the failure of the main
fixing point.
-The external surface of the unit, at various points, may exceed 80°C.
Never handle the unit until it’s on.
-Never install the fixture in an enclosed area lacking sufficient air flow.
-The ambient temperature should not exceed 40°C.
6.5 Level of protection against the penetration of solid and liquid matter:
-The projector is classified as an ordinary appliance and its protection level against the penetration of
solid and liquid matter is IP 65.
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 27 28

Comments to this Manuals

No comments