Delta 20-140 Service Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
309030 11
Setup
C. Test the spray pattern and atomization while keep-
ing the gun a consistent distance, about 6 to 8 in-
ches (150 to 200 mm), from the test piece.
D. If the spray pattern is too wide, reduce the fan air
pressure (or slightly close the fan adjustment valve
on manifold 243950).
NOTE: Reducing the fan air pressure to 0 psi (or
fully closing the fan adjustment valve) will produce
a round pattern.
E. Check the atomization quality again. Increase the
gun air supply pressure with the air pressure regu-
lator in 5 psi (34 kPa, 0.3 bar) increments until you
obtain the desired atomization.
F. If after increasing the gun air supply pressure the
atomization is still unacceptable, try installing a
larger fluid nozzle size to reduce the fluid velocity.
Repeat steps 6-B to 6-E until you obtain the
desired atomization.
Pressure Drop Chart
(for separate fan and atomizing air supplies)
5/16 inch (7.9 mm) I.D. hose
Recommended hose size to minimize excessive pressure drop. Expected pressure drops measured using 25 ft.
(7.625 m) long hose, with gun triggered.
Atomizing Air Regulator
Pressure Setting
psi (kPa, bar)
Atomizing Gun Inlet
Pressure
psi (kPa, bar)
Fan Air Regulator
Pressure Setting
psi (kPa, bar)
Fan Gun Inlet Pressure
psi (kPa, bar)
13.0 (91, 0.9) 10 (70, 0.7) 11.5 (80, 0.8) 10 (70, 0.7)
24.0 (168, 1.7) 20 (140, 1.4) 23.0 (161, 1.6) 20 (140, 1.4)
34.8 (244, 2.4) 30 (210, 2.1) 34.5 (241, 2.4) 30 (210, 2.1)
46.0 (322, 3.2) 40 (280, 2.8) 46.9 (328, 3.3) 40 (280, 2.8)
57.0 (399, 4.0) 50 (345, 3.4) 56.8 (398, 4.0) 50 (345, 3.4)
68.0 (476, 4.8) 60 (410, 4.1) 68.0 (476, 4.8) 60 (410, 4.1)
79.5 (556, 5.6) 70 (490, 4.9) 79.4 (556, 5.6) 70 (490, 4.9)
90.0 (630, 6.3) 80 (560, 5.6) 90.3 (632, 6.3) 80 (560, 5.6)
Page view 10