The alarm output port should not be connected to high power load directly (It shall be less than
1A) to avoid high current which may result in relay damage. Please use the co contactor to
realize the connection between the alarm output port and the load.
3. How to connect PTZ decoder
a. Ensure the decoder has the same grounding with DVR, otherwise you may not control the PTZ.
Shielded twisted wire is recommended and the shielded layer is used to connect to the grounding.
b. Avoid high voltage. Ensure proper wiring and some thunder protection measures.
c. For too long signal wires, 120 should be parallel connected between A, B lines on the far end
to reduce reflection and guarantee the signal quality.
d. “485 A, B” of DVR cannot parallel connect with “485 port” of other device.
e. The voltage between of A,B lines of the decoder should be less than 5v.
4. Please make sure the front-end device has soundly earthed.
Improper grounding may result in chip damage.
3.8.1 Alarm Input and Output Details
You can refer to the following sheet and X288H288H288HFigure 3-6X for alarm input and output information.
Figure 3-6
In the first line, from
the left to the right,:
12345
678910
11121314
1516
ALARM 1 to ALARM 16. The alarm becomes active in low voltage.
In the second line,
from the left to the
right:
NO1 C1
NO2 C2
NO3 C3
NO4 C4,
NO5 C5 NC5
The first four are four groups of normal open activation output
(on/off button)
NO5 C5 NC5 is a group of NO/NC activation output (on/off button)
CTRL 12V Control power output. You need to close the device power to cancel
the alarm.
+12V It is external power input. Need the peripheral equipment to provide
+12V power (below 1A).
Earth cable.
485 A/B 485 communication port. They are used to control devices such as
PTZ. Please parallel connect 120T between A/B cables if there are
too many PTZ decoders.T
3.8.2 Alarm Input Port
Please refer to the following sheet for more information.
z 4/8/16-ch grounding alarm inputs. (Normal open or Normal close type)