3. Instruction Set
3-197
API Mnemonic Operands Function
76
ASC
ASCII code conversion
Controllers
ES2/EX2 SS2 SA2
SE
SX2
Bit Devices Word devices Program Steps Type
OP
X Y M S K H KnX KnY KnM KnS T C D E F
S
D * * *
ASC: 11 steps
PULSE 16-bit 32-bit
ES2/EX2 SS2
SA2
SE
SX2 ES2/EX2 SS2
SA2
SE
SX2 ES2/EX2 SS2
SA2
SE
SX2
Operands:
S: English letters to be converted into ASCII code D: Device for storing ASCII code
Explanation:
1. The ASC instruction converts 8 English letters stored in S and save the converted ASCII code
in D. The value in S can be input by WPLSoft or ISPSoft.
2. If PLC is connected to a 7-segment display while executing ASC instruction, the error
message can be displayed by English letters
3. Flag: M1161 (8/16 bit mode switch)
Program Example:
When X0 = ON, A~H is converted to ASCII code and stored in D0~D3.
X0
ASC
A B C D E F G H
D0
D0
D1
D2
b15 b0
42H (B) 41H (A)
44H (D) 43H (C)
46H (F) 45H (E)
D3
48H (H) 47H (G)
Low byteHigh byte
When M1161 = ON, every
A
SCII code converted from
the letters will occupy the lower 8 bits (b7 ~ b0) of a
register and the upper 8 bits are invalid (filled by 0),
i.e. one register stores a letter
b15 b0
D0
D2
D4
D6
D1
D3
D5
D7
00 H
00 H
00 H
00 H
00 H
00 H
00 H
00 H
41H (A)
42H (B)
43H (C)
44H (D)
45H (E)
46H (F)
47H (G)
48H (H)
Low byte
High byte