IQ 100 Series ((130/140/150) Meter
Overview & Specifications
User and Installation Manual IM02601003E - September 2011 www.eaton.com 17
90ms
90ms
][
3600
][
Wa t tP
pulse
Watthour
Kh
sT
=
LED
OFF
LED
OFF
LED
OFF
IR LED Light Pulses
Through face plate
NO
C
NC
NO
C
NC
NO
C
NC
NO
C
NC
NO
C
NC
KYZ output
Contact States
Through Backplate
P
[
Watt
] - Not a scaled value
Kh
See Section 6-4 for values
On resistance, max.: 35Ω
Leakage current: 1µA@350V
Isolation: AC 3750V
Reset State: (NC - C) Closed; (NO - C) Open
Infrared LED:
Peak Spectral Wavelength: 940nm
Reset State: Off
Internal Schematic: Output timing:
(De-energized State)
Compliance
UL Listing: USL/CNL E185559
IEC 687 (0.5% Accuracy)
ANSI C12.20 (0.5% Accuracy)
ANSI (IEEE) C37.90.1 Surge Withstand
ANSI C62.41 (Burst)
CE Compliant
IEC1000-4-2: ESD
IEC1000-4-3: Radiated Immunity
IEC1000-4-4: Fast Transient
IEC1000-4-5: Surge Immunity
NO
C
NC
* P [Watt] - not a scaled value
Kh - see page 56 for values.