Delta 36-R31 User Manual Page 69

  • Download
  • Add to my manuals
  • Print
  • Page
    / 84
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 68
ACC-36E Manual
ACC-36E Layout & Pinouts 69
J1 Bottom: ADC9 through ADC12
J1 Bottom: D-sub DA-15F
Mating: D-sub DA-15M
2345
9101112
67
1314
8
15
1
Pin #
Symbol
Function
Description
1
+ADC9
Input
+Analog Input #9
2
+ADC10
Input
+Analog Input #10
3
+ADC11
Input
+Analog Input #11
4
+ADC12
Input
+Analog Input #12
5
Open
N/A
6
AGND
Common
Ground
7
+12V
Output
Positive supply
8
AGND
Common
Ground
9
-ADC9
Input
-Analog Input #9
10
-ADC10
Input
-Analog Input #10
11
-ADC11
Input
-Analog Input #11
12
-ADC12
Input
-Analog Input #12
13
Open
N/A
14
AGND
Common
Ground
15
-12V
Output
Negative supply
Note
The ±12V output can be used for an external device (i.e. sensor).
The drawn current should not exceed 0.5 Amperes.
The common ground (pin #7) is tied to the digital ground of the
UMAC rack.
J2 Bottom: ADC13 through ADC16
J2 Bottom: D-sub DA-15F
Mating: D-sub DA-15M
2345
9101112
67
1314
8
15
1
Pin #
Symbol
Function
Description
1
+ADC13
Input
+Analog Input #13
2
+ADC14
Input
+Analog Input #14
3
+ADC15
Input
+Analog Input #15
4
+ADC16
Input
+Analog Input #16
5
Open
N/A
6
AGND
Common
Ground
7
+12V
Output
Positive supply
8
AGND
Common
Ground
9
-ADC13
Input
-Analog Input #13
10
-ADC14
Input
-Analog Input #14
11
-ADC15
Input
-Analog Input #15
12
-ADC16
Input
-Analog Input #16
13
Open
N/A
14
AGND
Common
Ground
15
-12V
Output
Negative supply
Note
The ±12V output can be used for an external device (i.e. sensor).
The drawn current should not exceed 0.5 Amperes.
The common ground (pin #7) is tied to the digital ground of the
UMAC rack.