6 - English
FOREWORD
The 50-850 Dust Collector will connect to woodworking machines that accept a 4" (101.6 mm) diameter hose. The
50-850 comes with a five micron filter bag, one six mil plastic collection bag and a 4" x 5' (101.6 mm x 1524 mm)
collection hose.
FUNCTIONAL DESCRIPTION
EXTENSION CORDS
Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord
which has a 3-prong grounding type plug and matching receptacle which will accept the machine’s plug. When using an
extension cord, be sure to use one heavy enough to carry the current of the machine. An undersized cord will cause a drop
in line voltage, resulting in loss of power and overheating. Fig. D-1 or D-2, shows the correct gauge to use depending on
the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.
NOTICE: The illustration on the manual cover shows the current production model. All other illustrations contained in the
manual are representative only and may not depict the actual labeling or accessories included. These are intended to
illustrate technique only.
3. 240 VOLT SINGLE PHASE OPERATION
The motor supplied with your machine is a dual
voltage, 120/240 volt motor. It is shipped ready-
to-run for 120 volt operation. However, it can be
converted for 240 volt operation.
A qualified electrician should do the conversion, or
the machine can be taken to an Authorized Delta
Service Center. When completed, the machine must
conform to the National Electric Code and all local
codes and ordinances.
The machine is typically converted by re-wiring the
motor for 240 volts, installing a 240 volt plug on the
power supply cord and replacing the switch with one
that is rated for 240 volt operation.
Be sure the 240 volt plug is only used in an outlet
having the same configuration as the plug illustrated
in Fig. C. No adapter should be used with the 240
volt plug.
Fig. C
GROUNDED OUTLET BOX
CURRENT
CARRYING
PRONGS
GROUNDING BLADE
IS LONGEST OF THE 3 BLADES
Fig. D-1
Fig. D-2
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere Total Length Gauge of
Rating Volts of Cord in Feet Extension Cord
0-6 120
up to
25 18 AWG
0-6 120 25-50 16 AWG
0-6 120 50-100 16 AWG
0-6 120 100-150 14 AWG
6-10 120
up to
25 18 AWG
6-10 120 25-50 16 AWG
6-10 120 50-100 14 AWG
6-10 120 100-150 12 AWG
10-12 120
up to
25 16 AWG
10-12 120 25-50 16 AWG
10-12 120 50-100 14 AWG
10-12 120 100-150 12 AWG
12-16 120
up to
25 14 AWG
12-16 120 25-50 12 AWG
12-16 120
GREATER THAN 50 FEET NOT RECOMMENDED
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere Total Length Gauge of
Rating Volts of Cord in Feet Extension Cord
0-6 240
up to
50 18 AWG
0-6 240 50-100 16 AWG
0-6 240 100-200 16 AWG
0-6 240 200-300 14 AWG
6-10 240
up to
50 18 AWG
6-10 240 50-100 16 AWG
6-10 240 100-200 14 AWG
6-10 240 200-300 12 AWG
10-12 240
up to
50 16 AWG
10-12 240 50-100 16 AWG
10-12 240 100-200 14 AWG
10-12 240 200-300 12 AWG
12-16 240
up to
50 14 AWG
12-16 240 50-100 12 AWG
12-16 240
GREATER THAN 100 FEET NOT RECOMMENDED
In all cases, make certain that
the receptacle in question is properly grounded.
If you are not sure, have a qualified electrician
check the receptacle.