43
XT IEC Power Control
Contactors, Starters and Overload Relays
Product Selection
Table 65. Magnet Coil Suffix
For indicated coils, price adder of 10% must be applied to the contactor list price in Tables 59, 61 and 63.
With DC Operation: Integrated diode-resistor combination, coil rating 2.6W.
Available October 2005, Frame C – D only.
Figure 27. Wiring Diagram
Figure 28. Wiring Diagram
Table 66. Overload Relay Settings (A)
Coil Voltage Suffix Code
Frame A – B
110V 50 Hz, 120V 60 Hz A
220V 50 Hz, 240V 60 Hz B
230V 50 Hz F
24V 50/60 Hz T
24V DC TD
415V 50 Hz, 480V 60 Hz C
550V 50 Hz, 600V 60 Hz D
208V 60 Hz E
190V 50 Hz, 220V 60 Hz G
240V 50 Hz, 277V 60 Hz H
380V 50 Hz, 440V 60 Hz L
400V 50 Hz N
380V 60 Hz P
12V 50/60 Hz R
24V 50 Hz U
42V 50 Hz, 48V 60 Hz W
48V 50 Hz Y
120V DC AD

220V DC BD

12V DC RD

48V DC WD

Coil Voltage Suffix Code
Frame C – F
110V 50 Hz, 120V 60 Hz A
220V 50 Hz, 240V 60 Hz B
230V 50 Hz F
24V 50/60 Hz T
24 – 27V DC TD
415V 50 Hz, 480V 60 Hz C
550V 50 Hz, 600V 60 Hz D
208V 60 Hz E
190V 50 Hz, 220V 60 Hz G
240V 50 Hz, 277V 60 Hz H
380V 50 Hz, 440V 60 Hz L
400V 50 Hz N
380V 60 Hz P
12V 50/60 Hz R
24V 50 Hz U
42V 50 Hz, 48V 60 Hz W
48V 50 Hz Y
110 – 130V DC AD

200 – 240V DC BD

12 – 14V DC RD

48 – 60V DC WD

Coil Voltage Suffix Code
Frame G
100 – 120V 50/60 Hz A
190 – 240V 50/60 Hz B
24V 50/60 Hz T
24 – 27V DC TD
480 – 500V 50/60 Hz C
380 – 440V 50/60 Hz L
42 – 48V 50/60 Hz W
110 – 130V DC AD

200 – 240V DC BD

48 – 60V DC WD

Frame L – N
110 – 250V 40 – 60 Hz/DC A
250 – 500V 40 – 60 Hz/DC C
48 – 110V 40 – 60 Hz/DC Y

24 – 48V DC TD
Frame L – N, S-Series
110 – 120V 50/60 Hz A
220 – 240V 50/60 Hz B
Frame P – R
220 – 250V 50 – 60 Hz/DC B
K1M
15
642
K5M
1
3
3
5
6
4
2
K3M
13
5
642
U1
V1
W1
M1
3
M1
V2
W2
U2
A
C
B
K1M
15
642
K5M
15
642
K3M
1
33
35
642
U1
V1
W1
M1
3
M1
V2
W2
U2
A
C
B
K1M
1
2
3
4
5
6
K5M
1
2
3
4
5
6
K3M
1
35
642
C
A
Setting Starting
A
: I
N
x 0.58
Motor Protection in the Star and
Delta Configurations
15 sec
B
: I
N
x 1
Only partial motor protection in
star position
15 – 40 sec
C
: I
N
x 0.58
Motor not protected in star
position
Timing Relay set to
approximately 10 sec
> 40 sec
Page view 44