Delta Three Phase 1342457 06-03-05 Service Manual Page 75

  • Download
  • Add to my manuals
  • Print
  • Page
    / 188
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 74
June 2005
CAT.02.02.S.K.CD For more information visit: www.EatonElectrical.ca
73
XT IEC Power Control
Contactors, Starters and Overload Relays
Technical Data and Specifications
Table 109. AC Ratings (Continued)
At maximum permissible ambient temperature.
Example —
The transformer has a nominal current of 10A with an inrush current of 18 times the nominal current. So, the contactor must have an AC-3 current of
18/6 x 10A = 30A. Using an XTCE032C (32A AC-3) contactor is recommended.
Description XTCE650N XTCE750N XTCE820N XTCEC10N XTCEC14P XTCEC20R
AC-1 Operation
Conventional Free Air Thermal Current,
3-Pole, 50 – 60 Hz
at 40°C (I
th
)
at 50°C (I
th
)
at 55°C (I
th
)
at 60°C (I
th
)
1041
931
888
850
1102
986
940
900
1225
1095
1044
1000
1225
1095
1044
1000
1714
1533
1462
1400
2450
2190
2089
2000
Conventional Free Air Thermal Current,
1-Pole (I
th
)
2125 2250 2500 2500 3500 5000
AC-3 Operation
Rated Operational Current, 50/60 Hz
(I
e
)
in amperes
220/230V
240V
380/400V
415V
440V
500V
660/690V
1000V
650
650
650
650
650
650
650
435
750
750
750
750
750
750
750
580
820
820
820
820
820
820
820
580
1000
1000
1000
1000
1000
1000
1000
700
Rated power (P) in kilowatts
220/230V
240V
380/400V
415V
440V
500V
660/690V
1000V
205
225
355
390
420
470
630
600
240
260
400
455
480
550
720
800
260
285
450
500
525
600
750
800
315
340
560
610
650
730
1000
1000
AC-4 Operation
Rated Operational Current, 50/60 Hz
(I
e
)
in amperes
220/230V
240V
380/400V
415V
440V
500V
660/690V
1000V
512
512
512
512
512
512
512
348
576
576
576
576
576
576
576
464
656
656
656
656
656
656
656
464
800
800
800
800
800
800
800
700
Rated power (P) in kilowatts
220/230V
240V
380/400V
415V
440V
500V
660/690V
1000V
161
176
280
307
326
370
494
509
181
200
315
346
367
417
556
678
209
228
355
394
418
474
633
678
260
280
450
490
520
590
780
1000
AC-6A Operation
Transformer Loads Values are application specific. Calculation is I
e
AC-3
= X / 6 * I
e Transformer where X is the inrush current of the
transformer and
I
e Transformer is the nominal current.
AC-6B Operation
Capacitor Loads
Individual compensation rated operational cur-
rent I
e
of three-phase capacitors in amperes
Up to 525V
690V
463
265
463
265
463
265
463
265
Maximum inrush current peak (x I
e
)30 303030—
Component Lifesaving (Operations) 100,000 100,000 100,000 100,000
Maximum Operating Frequency (ops/hr) 200 200 200 200
Page view 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 187 188

Comments to this Manuals