4. Make certain air cylinder rod is retracted completely
into cylinder (E) Fig. 27. Loosen locknut (K) Fig. 27, and
unscrew hex end of clevis rod (L) until holes line up with
holes in bracket (N). Using retaining clip (A) and retaining
pin (B), which were removed in STEP 1, fasten clevis (L)
to bracket (N). Retighten locknut (K) Fig. 27. NOTE: It
may be necessary to loosen screws (R) Fig. 28, in order
to get pin to line up with clevis.
5. Insert black air supply line (S) Fig. 28, into top fitting
(G) of the air cylinder and blue air supply line (V) into
bottom fitting (H) of the air cylinder as shown. NOTE:
Push end of air lines as far as they will go into the
fittings.
Fig. 29
B
C
A
Fig. 30
B
A
Fig. 31
E
D
Fig. 32
E
D
F
A
ASSEMBLING TABLE
AIR CYLINDER CLAMPS
(For 32-326 Pneumatic Line Boring Machine
Only)
1. Assemble clamp bracket (A) Fig. 29, to bottom of
table using two 1/4-20x1-1/4" flat head screws (B) and
1/4-20 hex lock nuts (C).
2. Figure 30 illustrates one of the two clamp brackets
(A) assembled to the table with the two 1-1/4" long flat
head screws (B). Assemble remaining clamp bracket to
other end of table in the same manner.