23
Fig. 67
CORRECT OPERATING
TECHNIQUE
(For 32-326 Pneumatic Line Boring Machine
Only)
The following is a typical example of a line boring
operation and how the electric/air controls function:
1. Place the workpiece (A) on the table and against the
fence as shown in Fig. 66.
2. Depress and hold the start button (B) Fig. 67. As
soon as the start button (B) has been depressed, the two
air clamps (C) will activate and the air clamp plungers (C)
will lower, holding the workpiece firmly against the table.
The motor will also turn on and the boring head will lower
to its pre-set depth. After the boring operation is
completed, the boring head will raise up and the motor
will shut off. If you release the start button at any time
during the boring cycle, the motor will shut off and the
boring head will return to the up position.
Fig. 66
3. Figure 68 illustrates the completed boring operation
with the boring head in the raised position. Note that the
two air clamp plungers (C) are still in the down position
clamping the workpiece against the table. NOTE: The
motor cannot be turned on until the reset button is
pressed as explained in STEP 4.
4. Press the reset button (D) Fig. 69. This will raise the
two air clamp plungers (C) allowing you to reposition the
work-piece and re-start the machine.
Fig. 68