20
11. Loosen locknut (C), and turn adjusting screw (D)
counter clockwise, on turn.
12. T urn the blade tilting handwheel until the blade is 45
degrees to the t able.
13. T urn adjusting head screw (D) clockwise, until it just
cont act s the casting on the front trunnion, then tighten
locknut (C), until it is locked into place.
14. Check to see if the tilt indicator pointer point s to the 45
degree mark on the scale. Adjust if necessary
ADJUSTING TABLE
The saw table has been aligned at the factory so the miter
gage slot s are p arallel to the saw blade; however, it is
recommended to check the alignment before initial
operation as follows:
1. DISCONNECT THE MACHINE FROM THE POWER
SOURCE.
2. Place a combination square (A) Fig. 70, on the t able
with one edge of the square in the miter gage slot, as
shown, and adjust the square so the rule just touches one
of the teeth on the saw blade at the forward position, as
shown in Fig. 70. Lock the square in this position.
3. Rotate the saw blade so that the same tooth you used
in STEP 2 is in the rear position, as shown in Fig. 71, and
check this dist ance. Both the front and rear measurements
should be identical.
4. If an adjustment is necessary, loosen the four screws
that hold the t able to the saw cabinet.
5. Shif t the t able until a position is found which brings the
saw blade in the center of the t able insert slot, and p arallel
to the miter gage slot.
6. Tighten the four screws that were loosened in STEP 4.
MITER GAGE OPERATION
AND ADJUSTMENT
Insert the miter gage bar into the miter gage slot and
assemble the washer and lock handle (A) Fig. 72, to the
miter gage bar as shown.
The miter gage is equipped with adjust able index stop s at
90 degrees and 45 degrees right and left. Adjustment to
the index stop s can be made by tightening or loosening
the three adjusting screws (B) Fig. 73.
To rot ate the miter gage, loosen lock knob (A) Fig. 73, and
move the body of the miter gage (C), to the desired angle.
Fig. 70
Fig. 71
Fig. 72
Fig. 73
Fig. 74
A
C
A
B
D