CAT.02.02.S.K.CD For more information visit: www.EatonElectrical.ca
159
XT IEC Power Control
Combination Motor Controllers
Product Family Overview
Contents
Description Page
Standards and
Certifications . . . . . . . . . . . . 160
Accessories . . . . . . . . . . . . . . . 160
Catalog Number
Selection . . . . . . . . . . . . . . . . 161
Product Selection . . . . . . . . . . 162
Technical Data and
Specifications . . . . . . . . . . . . 167
Product Description
The new Cutler-Hammer
®
XT
IEC Open
Non-reversing and Reversing Manual
Motor Controllers from Eaton’s electrical
business combine a Manual Motor
Protector with an IEC Contactor(s) to
provide a complete motor protection
solution by combining motor disconnect
function, thermal overload protection,
magnetic short circuit protection and
remote control operation in one com-
pact, assembled unit. These assembled
Manual Motor Controllers cover
motors with FLA ratings from 0.10A to
52A.
The UL 508 Type F labeled Combination
Motor Controller (CMC) includes a Line
Side Adapter (LSA). These assembled
Combination Motor Controllers cover
motors with FLA ratings from 0.10A to
52A.
Application Description
The XT IEC Non-reversing and Revers-
ing Manual and Combination Motor
Controllers can be used in the follow-
ing applications:
XTSC and XTSR
Manual Motor Controller for Single
and Multi Motor Panels — The pre-
assembled XT Manual Motor Con-
trollers (MMC) combine a Manual
Motor Protector, a Wiring Connector
Link and IEC Contactor. The XTPR
Manual Motor Protectors are UL
listed as
UL 508, Type E Self-
Protected Manual Combination
Starters. MMCs can also be field
installed with separate MMP, WCL
and Contactor(s). An IEC magnetic
contactor has been added to allow
for remote operation of the motor
circuit.
XTFC and XTFR
Combination Motor Controller (UL
508, Type F), for Single and Multi
Motor Panels — The preassembled
IEC Combination Motor Controllers
combine a Line Side Adapter, Man-
ual Motor Protector, Wiring Connec-
tor Link and IEC Contactor. The
XTPR Manual Motor Protectors are
UL listed as UL 508, Type E Self-
Protected Manual Combination
Starters. This UL listing allows these
devices to be used in motor circuits
without having to add separate
branch short circuit protection. An
IEC magnetic contactor has been
added to allow for remote operation
of the motor circuit.
Group Motor Installations — Since
the Manual Motor Protectors
(Manual Combination Starters) are
UL listed for Group Motor Installa-
tions, the IEC Manual Motor Control-
lers provide a compact, assembled
package for Group Motor Installa-
tions up to 600V.
For Group Installations (in-panel
SCPD) applying the traditional 1/3 tap
rule, the Manual Motor Protectors and
Combination Motor Controllers may
be used on 480V Delta systems along
with 480Y/277V and 600Y/347V slash
rated Wye systems. For Group Installa-
tions, applying the more recent 1/10
tap conductor rule, a maximum 240V
Delta is permitted or 480Y/277V and
600Y/347V slash rated Wye systems.
For actual UL 508 Type E/F applications
(out-of-panel upstream feeder Short-
Circuit Protective Device [SCPD] only),
a maximum 240V Delta is permitted or
480Y/277V and 600Y/347V slash rated
Wye systems.
For Manual “At Motor” Disconnect
applications, a maximum 240V Delta is
permitted or 480Y/277V and 600Y/347V
slash rated Wye systems.
Features
ON/OFF rotary handle with lockout
provision
Visible trip indication
Test trip function
Motor applications from 0.11A to
50A
Class 10 overload protection
Built-in heater and magnetic trip
elements to protect the motor
Phase loss sensitivity
Type 2 coordination
Ambient compensated up to 55°C
[140°F]
Control inputs located at front of
starter for easy access and wiring
Wide range of coils
DIN Rail mount — XTSC…BB_
Mounting plates — XTSC…BC_,
XTSC…D motor controllers
Adjustment dial for setting motor
FLA
Short circuit trip at 14 times the
maximum setting of the FLA
adjustment dial
UL 508 Type F CMC High Fault Short
Circuit Ratings: Refer to Table 206.
1NO-1NC Auxiliary Contact as
standard on Manual Motor Protector
XT Combination Motor Controller
and Manual Motor Controller