MMC120 Specifications
Power Requirements
Back plane +5V @ 1 Amp
Environment
Operating temperature +32 to +140°F (0 to +60°C)
Non-operating temperature -40 to +185°F (-40 to +85°C)
Storage temperature -40 to +185°F (-40 to +85°C)
Humidity 93%, non-condensing
Agency compliance UL, CSA, CE
ESD Immunity 8kV
Vibration resistance 1 g at 60 Hz to 500 Hz for 23 minutes
0.075 mm displacement from 10 Hz to 60
Hz
Shock resistance 30 g for 11 milliseconds
Transducer Inputs
MDT interface Direct connection
Signal compatibility Differential (RS-422) or single-ended (TTL
level)
Transducer compatibility Start/Stop or Pulse Width Modulated
Drive Inputs
Output isolation Optically isolated,
2500VAC withstand voltage
Range
±10V @ 5mA (2k or greater load)
(use optional VC2100 module for current
drive; ±10mA to ±100mA in 10mA steps)
Resolution 12 bits