Delta 36-412 Service Manual Page 54

  • Download
  • Add to my manuals
  • Print
  • Page
    / 76
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 53
--- 50 ---
Item
Phenomenon
Cause
Factory
standard
Inspection, repair or
adjustment
a Same as item 10- a
to d .
b Encoder failure
c Cord (D), cord (C)
330 mm, cord (A)
100 mm, cord (C)
330 mm and cord (A)
310 mm are
disconnected.
d Deformation of spring
plate
e Loose spring plate
------
• Same as item 10- a to d .
• Replace the Encoder [127].
• Replace the Encoder [33].
• Replace Cord (D) [114], Cord
(C) 330 mm [125] or Cord (A)
100 mm [112].
• Replace Cord (D) [114], Cord
(C) 300 mm [124] or Cord (A)
310 mm [123].
Adjust the squareness of the
miter angle of the main body
and replace the Spring Plate
[76].
Adjust the squareness of the
miter angle of the main body
and replace the Spring Plate
[76].
11
Digital display does not
indicate properly.
(Model C 12LDH)
(Miter angle)
(Bevel angle)
(Miter angle)
(Bevel angle)
a Monitor failure
a Monitor failure
• Replace the Monitor Ass'y
[118].
• Replace the Monitor Ass'y
[118].
12
Angle indicated on the
digital display can not
be reset.
13
Back light of digital
display can not be
turned on/off.
(Model C 12LDH)
Page view 53