Delta Three Phase 1342457 06-03-05 Service Manual Page 120

  • Download
  • Add to my manuals
  • Print
  • Page
    / 188
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 119
June 2005
118
For more information visit: www.EatonElectrical.ca CAT.02.02.S.K.CD
XT IEC Power Control
Contactors and Starters — Enclosed Control
Modification Codes
Table 147. C Control Power Transformer, IT. Power Supplies, Control
Relays, Cover Control (not elsewhere defined), Current Transformers,
Compelling Relay, Control Wiring, Control Circuit Breaker, Separate
Control, Customer-Supplied Components, Contactors, Counter, E-Stop
Relay, Separate Source Disconnect
Consult Eaton.
Table 147. C — Control Power Transformer, IT. Power Supplies, Control
Relays, Cover Control (not elsewhere defined), Current Transformers,
Compelling Relay, Control Wiring, Control Circuit Breaker, Separate
Control, Customer-Supplied Components, Contactors, Counter, E-Stop
Relay, Separate Source Disconnect (Continued
)
Consult Eaton.
Modification Catalog
Number
Suffix
Description Adder
Control
Power
Transformers
Make sure
8th character
specifies
primary/
secondary
voltage.
C1
Standard Size Control Transformer,
120V/60 Hz, 110V/50 Hz Secondary with
2 Primary and 1 Secondary Fuse
Size A – H
C2 Standard Size Control Transformer,
24V/60 Hz Secondary with 2 Primary
and 1 Secondary Fuse
Size A – H
C42
50 VA Extra Capacity CPT 120V/60 Hz,
110V/50 Hz with 2 Primary and1 Secondary
Size A – H
C3
100 VA Extra Capacity CPT, 120V/60 Hz,
110V/50 Hz Secondary with
2 Primary and 1 Secondary Fuse
Size A – H
C4
100 VA Extra Capacity CPT, 24V/60 Hz
Secondary with 2 Primary and
1 Secondary Fuse
Size A – H
C5
200 VA Extra Capacity CPT, 120V/60 Hz,
110V/50 Hz Secondary with 2 Primary
and 1 Secondary Fuse
Size A – H
C6
200 VA Extra Capacity CPT, 24V/60 Hz
Secondary with 2 Primary and
1 Secondary Fuse
Size A – H
C7
300 VA Extra Capacity CPT, 120V/60 Hz,
110V/50 Hz Secondary with 2 Primary
and 1 Secondary Fuse
Size A – H
C8
400 VA Extra Capacity CPT, 120V/60 Hz,
110V/50 Hz Secondary with 2 Primary
and 1 Secondary Fuse
Size A – H
C9
1 kVA Extra Capacity CPT, 120V/60 Hz,
110V/50 Hz Secondary with 2 Primary and
1 Secondary Fuse
C10
2 kVA Extra Capacity CPT, 120V/60 Hz,
110V/50 Hz Secondary with 2 Primary and
1 Secondary Fuse
C11
Control Transformer — Order by
Description
C34
CPT with Power Supply
Modification Catalog
Number
Suffix
Description Adder
Power
Supplies
C27 Separate Control 120V AC to 24V DC
C28 Power Supply with Extra Capacity —
Order by Description
Control
Relays
C12
4-Pole Interposing Relay, 600V
(2NO/2NC)
C13
Run Relay, 24V DC (MVX)
C14
4-Pole, Unwired, A600 Rtg. —
2NO-2NC
C15
8-Pole, Unwired, A600 Rtg. —
4NO-4NC
C16
Control Relay — Order by
Description
Cover
Control
C17
Convert Position 7 to E30 Type
Cover Control
C19
Lock-Off Attachment Added on
Cover Control
C29
Change to 10250T Cover Controls
Current
Trans-
former(s)
C21
In Phase 1
C22
In Phases 1 and 2
C23
In 3 Phases
Compelling
Relay
C25
Control
Wiring
C26
Omit Control Wiring
N/C
C30
With Separate Control Wiring and
Two 250V Fuses in Holder
C31
With Common Control Wiring and
Two 600V (Class C) Fuses in Holder
C33
Control Wiring Type — Order by
Description
Control
Circuit
Breaker
C32
Order by Description
Separate
Control
C35
Wired for Separate Control
(Reduced Voltage)
Customer
Supplied
Components
C36
Customer Supplied Components to
Be Installed
C37
Customer Supplied Wiring Diagram
to Use
Contactor/
Starter
C40
Contactor/Starter — Order by
Description
Counter
C41
Operations Counter
E-Stop Relay
C43
E-Stop Relay (DeviceNet)
Separate
Source
Disconnect
C45
IEC Separate Source Disconnect for
Control Circuitry
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . MC7
Page view 119
1 2 ... 115 116 117 118 119 120 121 122 123 124 125 ... 187 188

Comments to this Manuals

No comments