Delta Three Phase 1342457 06-03-05 Service Manual Page 122

  • Download
  • Add to my manuals
  • Print
  • Page
    / 188
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 121
June 2005
120
For more information visit: www.EatonElectrical.ca CAT.02.02.S.K.CD
XT IEC Power Control
Contactors and Starters — Enclosed Control
Modification Codes
Table 155. P — Pilot Lights, Pushbuttons, Phase Relays, Potential
Transformers, Power Factor Correction Capacitors, Program Timer,
Percentage Timer, Photocell
Consult Eaton.
Table 155. P — Pilot Lights, Pushbuttons, Phase Relays, Potential
Transformers, Power Factor Correction Capacitors, Program Timer,
Percentage Timer, Photocell (Continued)
Consult Eaton.
Modification Catalog
Number
Suffix
Description Adder
Push-to-Test
Pilot Lights
P1
Push-to-Test Pilot Light (Red RUN)
Wired to Coil
P2
Push-to-Test Pilot Light (Green OFF)
Wired in Series with Auxiliary Contact
P3
Combination of P1 and P2 Above
P4
Push-to-Test Pilot Light (Amber RUN)
Wired to Coil
P49
Push-to-Test Pilot Light (Green RUN)
P54
Push-to-Test Pilot Light — Red
BYPASS (MVX)
P55
Push-to-Test Pilot Light — Amber
INVERTER ENABLE (MVX)
P56
Push-to-Test Pilot Light — Red
INVERTER RUNNING (MVX)
P57
Push-to-Test Pilot Light — Green STOP
Pushbuttons
P5
EMERGENCY STOP — Mushroom
Head
P6
Pushbutton Omitted
P7
START/STOP
P8
ON/OFF
P9
START
P10
ON
P11
OFF
P12
FORWARD/REVERSE/STOP
P13
FAST/SLOW/STOP
P14
FAST/OFF/SLOW
P15
HIGH/LOW/STOP
P16
HIGH/LOW
P17
SLOW/FAST
P18
Pushbutton with Legend Plate
P52
UP/STOP/DOWN
P53
OPEN/STOP/CLOSE
P73 START/STOP Pushbuttons Located in Top
2 Holes
Pilot Lights
P19
With 1 Amber Pilot Light Marked
POWER AVAILABLE Wired to Load
Side of 2 Fuses or Circuit Breaker
P20
Pilot Light (Amber RUN) Wired to Coil
P21
With 1 Red Pilot Light Marked RUN
Wired thru NO Auxiliary Contact
P22
With 1 Push-to-Test Red Light Marked
RUN Wired thru NO Auxiliary Contact
P23
Pilot Light — Red RUN
P24
Pilot Light — Red ON
P25
Pilot Light — Green OFF
P26
Pilot Light — Order by Description
P29
Pilot Light — Red STOP
Modification Catalog
Number
Suffix
Description Adder
Pilot Lights
(Continued)
P58
Pilot Light — Red BYPASS (MVX)
P61
Pilot Light — Green STOP
P62
FORWARD/REVERSE Red Pilot Lights
P63
UP/DOWN Red Pilot Lights
P64
OPEN/CLOSE Red Pilot Lights
P65
HIGH/LOW Red Pilot Lights
P66
FAST/SLOW Red Pilot Lights
P67
Green RUN Light
P68
LED Bulbs
P69
Blue OVERLOAD Light
Illuminated
Pushbutton
P27
Illuminated Pushbutton — Order by
Description
Phase Loss
Relay
P28
Phase Loss Relay
Phase Rever-
sal Relay
P30
Phase Reversal Relay
Phase
Unbalance
Relay
P32
Phase Unbalance Relay
Phase
Monitoring
Relay
P34
Phase Monitoring Relay
Power
Factor
Correction
Capacitors
P38
/F1 20KVAR
/F2 25KVAR
/F3 30KVAR
/F4 35KVAR
/F5 40KVAR
/F6 45KVAR
/F7 50KVAR
/F8 60KVAR
/F9 70KVAR
/F10 75KVAR
/F11 80KVAR
/F12 90KVAR
/F13 100KVAR
/F14 125KVAR
/F15 150KVAR
/F16 175KVAR
/F17 200KVAR
/F18 225KVAR
/F19 250KVAR
/F20 300KVAR
/F21 350KVAR
/F22 400KVAR
Potential
Trans-
formers
P39
Potential Transformer — Wired L1 – L2
P40
Potential Transformer — Wired L1– L2
and L2 – L3
P41
Potential Transformer — 3 Phases
Program
Timers
P43
15-Minute Program Timer
P44
24-Hour Program Timer
P45
7-Day Program Timer with Day Omission
Feature
Percentage
Timers
P47
15-Minute Percentage Timer
P48
60-Minute Percentage Timer
Photocell
P70
Photoelectric Receptacle with Photocell
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . MC7
Page view 121
1 2 ... 117 118 119 120 121 122 123 124 125 126 127 ... 187 188

Comments to this Manuals