CAT.02.02.S.K.CD For more information visit: www.EatonElectrical.ca
57
XT IEC Power Control
Contactors, Starters and Overload Relays
Technical Data and Specifications
Table 99. XT Contactors Technical Data and Specifications — Frame C – D (Continued)
Frame F – G
Table 100. XT Contactors Technical Data and Specifications — Frame F – G
Contact Eaton.
Description XTCE018C XTCE025C XTCE032C XTCE040D XTCE050D XTCE065D
General (Continued)
Mounting Position, AC and DC operated
Ambient Temperature -25 to 60°C
[-13 to 140°F]
-25 to 60°C
[-13 to 140°F]
-25 to 60°C
[-13 to 140°F]
-25 to 60°C
[-13 to 140°F]
-25 to 60°C
[-13 to 140°F]
-25 to 60°C
[-13 to 140°F]
Ambient Storage Temperature -40 to 80°C
[-40 to 176°F]
-40 to 80°C
[-40 to 176°F]
-40 to 80°C
[-40 to 176°F]
-40 to 80°C
[-40 to 176°F]
-40 to 80°C
[-40 to 176°F]
-40 to 80°C
[-40 to 176°F]
Environmental
Mechanical Shock Resistance (IEC/EN 60068-2-27)
Main contact — NO Contact
Auxiliary contact — NO Contact
Auxiliary contact — NC Contact
10
7
5
10
7
5
10
7
5
10
7
5
10
7
5
10
7
5
Overvoltage Category / Pollution Degree III/3 III/3 III/3 III/3
Description XTCE080F XTCE095F XTCE115G XTCE150G
General
Standards IEC/EN 60947, VDE 0660, UL, CSA, CCC, RoHS
Weights in kg [Lb]
AC operated
DC operated
2
2.1
2
2.1
2
2.1
2
2.1
Mechanical Life 10,000 10,000 10,000 10,000
Mechanical Operating Frequency (ops/hr)
AC operated
DC operated
5000
1000
5000
1000
5000
1000
5000
1000
Mechanical Operating Frequency (ops/hr)
AC-1; 400V I
e
AC-3; 400V I
e
AC-4; 400V I
e
800
800
300
800
800
300
800
800
300
800
800
300
Climatic Proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60 068-2-30
Insulation Voltage (U
i
) VAC 1000 1000 1000 1000
Impulse Withstand Voltage (U
imp
) VAC 8000 8000 8000 8000
Operational Voltage (U
e
) VAC 1000 1000 1000 1000
Safe Isolation to VDE 0106 Part 101 and Part 101/A1
Between coil and contacts (VAC)
Between contacts (VAC)
440
440
440
440
440
440
440
440
Making Capacity (Amps) 1120 1330 1610 2100
Breaking Capacity (Amps)
220/230V
380/400V
500V
660/690V
1000V
800
800
800
650
320
950
950
950
800
370
1150
1150
1150
1100
450
1500
1500
1500
1320
550
Short-Circuit Protection Rating Maximum Fuse
Type 2 Coordination
400V; gG/gL 500V
690V; gG/gL 690V
Type 1 Coordination
400V; gG/gL 500V
690V; gG/gL 690V

Degree of Protection IP00
Protection Against Direct Contact when
Actuated from Front (IEC 536)
Finger- and back-of-hand proof
180°
90°
90°
30
°
180°
90°
90°
30
°
Page view 58