Delta MS265 Instruction Manual Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 23
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
20
BRUSH INSPECTION
AND REPLACEMENT
Brush life varies. It depends on the load on the motor.
Check the brushes after the first 50 hours of use for a
new machine or after a new set of brushes has been
installed. After the first check, examine them after about
10 hours of use until such time that replacement is
necessary. To inspect the brushes, proceed as follows:
DISCONNECT MACHINE FROM POWER
SOURCE.
1. Remove three screws (A) Fig. 46 and remove motor
cover (B).
3. Fig. 48 illustrates one of the brushes (E) removed
from the holder (C). When the carbon on either brush (E)
is worn to 3/16 in length or if either spring (F) or shunt
wire is burned or damaged in any way, replace both
brushes. If the brushes are found to be serviceable after
re-moving, reinstall them in the same position.
2. The brushes are located in the two holders (C) Fig. 47.
Remove spade type terminal connector (D) and pull out
brush holders (C).
A
B
Fig. 46
Fig. 47
B
C
C
Fig. 48
F
E
B
Page view 19
1 2 ... 15 16 17 18 19 20 21 22 23

Comments to this Manuals

No comments