Step 8: Test an Actuator
deltamotion.com 15
8. In the Command Tool, click Send.
The axis should move, and the Control
Output (in the Axis Status Registers)
should be 0.100.
9. If the axis did not move, resend the command with a larger
Output until the axis moves.
Note: If you are using the Enable Output for enabling the
actuator, such as a motor drive, then you first need to set the
Enable Output before trying to move the actuator. For details,
see the Set Enable Output (67) Command topic in the
RMCTools help.
10. Now stop the axis:
In the Command tool, enter 0 in
the Output box and click Send.
11. Repeat these steps to move the axis in the other direction. In the
Direct Output command, use a negative Output.
Move the axis back and forth through the entire travel range to
make sure the machine is operating properly.