ADVANCED KWH/DEMAND METER
H-SERIES CLASS 500 SUBMETERS
Voltage Input Up to 600 VAC RMS available,
50/60Hz
Communication
Modbus RTU or TCP/IP
BACnet IP or MS/TP
LonWorks
Input
Voltage Configuration 3-wire (Delta) or 4-wire (WYE)
CT Input
0-2 VDC current sensors included
Available CT's Sensors - Up to 3200 Amp RMS
AC available
Overload Rating
Voltage Overload +25% continuously; +100% for 20
cycles
Current Sensor
Overload 100% for 1 minute without damaging
meter
Accuracy Certified to ANSI C12.20
Range
(4 Wire Wye) 115/208 VAC: 100, 200, 400, 800,
1600, 3200 Amp
(4 Wire Wye) 277/480 VAC: 100, 200, 400, 800,
1600, 3200 Amp
(3 Wire Delta) 220/240 VAC: 100, 200, 400, 800,
1600, 3200 Amp
(3 Wire Delta) 480 VAC: 100, 200, 400, 800, 1600,
3200 Amp
Operating Temperature
NEMA 4 (Outdoor) Housing: -4° to 158°F
(-20° to 70°C)
NEMA 12 (Indoor) Housing: -4° to 122°F
(-20° to 50°C)
Operating Humidity 0 to 95% RH (non-condensing)
Housing Type
Models with R NEMA 4
Models without R NEMA 12
Dimensions-Meter 7.5"H x 7"W x 3.75"D
(19.1 x 17.8 x 8.3 cm)
Dimensions-Current Sensors Interior Window
100A and 200A = 7/8" x 1-1/2"
400A = 1-1/2" x 2-3/4"
800A and 1600A = 3-1/4" x 4-1/2"
3200A = 5-7/16" x 7-7/8"
Approvals UL file#E249361
Battery
Description
Non-rechargeable cell used for
memory retention
Manufacturer Eagle-picher
Mfg Part No. LTC-3PN
Working Voltage 3.5 Vdc
Current Capacity 350 mAHr
Electrolyte Lithium thionyl nitrate
Warranty 1 year
DESCRIPTION
The H-Series Class 500 Submeters come with enclosure,
display, and does include split core current sensors. Available
outputs include pulse, LonWorks, BACnet, BACnet IP,
Modbus RTU, or Modbus TCP. There are 38 different points
of information available on the communicating models. The
dual protocol output allows operation for both RS-485 and
Ethernet communication simultaneously. In addition, they will
accept up to two pulse inputs from other meters (water, gas,
sewer, etc.) and communicate this information as two more
data points. Accuracy meets or exceeds +/- 0.5%.
FEATURES
Direct-read 8-digit LCD display of cumulative kWh
Includes 0-2 volt output split-core current sensors
Remote mounting of current sensors up to 500 feet
from meter (using 22 Awg wire)
Current sensor installation diagnostic indicator
Available in standard JIC Industrial-grade steel
enclosure
UL Listed; meets or exceeds ANSI C12 national
accuracy standards
Optional power failure contact for alarming
Dual protocol output
SPECIFICATIONS
H Series Class 500
March 2014