Chapter 3 Specifications for Products
Analog-to-digital
conversion
Current input
Fiducial error
(Room
temperature) (The
number of input
currents which are
averaged is 100.)
±0.1%
Fiducial error (Full
temperature
range) (The
number of input
currents which are
averaged is 100.)
±0.2%
Linearity error
(Room
temperature)
±0.05%
Linearity error
(Full temperature
range)
±0.23%
Hardware
resolution
16 bits
Input impedance 250
Absolute input
range
±32 mA
Functional specifications for the digital-to-analog conversion
Digital-to-analog
conversion
Voltage output
Rated output
range
±10 V 0 V~10 V ±5 V 0 V~5 V 1 V~5 V
Hardware output
range
-10.1 V~10.1 V -0.1 V~10.1 V -5.05 V~5.05 V -0.05 V~5.05 V 0.95 V~5.05 V
Fiducial error
(Room
temperature) (The
number of output
voltages which are
averaged is 100.)
±0.02%
Fiducial error (Full
temperature
range) (The
number of output
voltages which are
averaged is 100.)
±0.04%
Linearity error
(Room
temperature)
±0.004%
Linearity error
(Full temperature
range)
±0.004%
Hardware
resolution
16 bits
Permissible load
impedance
1 k~2 M: ±10 V and 0 V~10 V
500 : 1 V~5 V
3-44