Delta D25886 User Manual Page 113

  • Download
  • Add to my manuals
  • Print
  • Page
    / 339
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 112
4. Motion Control Instructions
4-72 DVP-MC operating manual
From the figures above, you can see the slave axis position of the second key point need be modified, i.e. the
value of D32770 need be done. Modify the value from 360 to 540 via the instruction "MOV-R".
The cam curve parameter table is shown below after being modified.
Key point serial
no.
Master axis
position
Slave axis
position
Velocity Acceleration
1 D28672=0 D32768=0 D36864=0 D40960=0
2 D28674=180 D32770=540 D36866=0 D40962=0
3 D28676=360 D32772=0 D36868=0 D40964=0
And then switch electronic cam curve by executing the instruction "DMC_CamSet".
Sequence chart as below:
When M1= On and M0 turns off -> on, “DMC_CamSet” is executed; M10 turns On after the execution of
“DMC_CamSet” is finished , which indicates that the register value of e-cam key point has been
switched to the newest key point parameter. The revised parameter value will be ineffective till the
current cam cycle is over.
Please carefully check the master axis position, slave axis position, velocity, and acceleration of the
cam key point which need be revised so as to make sure the new cam curve is reasonable.
Page view 112
1 2 ... 108 109 110 111 112 113 114 115 116 117 118 ... 338 339

Comments to this Manuals