Delta D25886 User Manual Page 63

  • Download
  • Add to my manuals
  • Print
  • Page
    / 339
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 62
4. Motion Control Instructions
4-22 DVP-MC operating manual
4.4.4. MC_MoveSuperImposed
API
Controller
04
MC_MoveSuperImposed
Superimposed motion
10MC11T
Explanation of the Instruction:
MC_MoveSuperImposed is applied to control the terminal actuator to chase for a given distance at a given
speed, acceleration and deceleration in current motion status. When this instruction is executed, the
execution of the former instruction will not be terminated, the two instructions will be executed together, the
distance, velocity, acceleration and deceleration will enter the real-time superposition. When one of the two
instructions reaches the given velocity, the acceleration will become 0. When the execution of one instruction
is finished, the speed, acceleration and deceleration will not be superimposed any more and meanwhile, the
other instruction is still being executed independently.
Explanation of input and output parameter of the instruction:
Parameter
name
Explanation
Data
type
Available
device
Axis The node address of servo drive UINT Constant, D
Execute
This instruction is executed when “Execute” turns from Off
to On.
BOOL
M,I,Q,
Constant
Distance
The additive distance for terminal actuator with the unit:
Unit.
REAL Constant, D
Velocity
The additive speed for terminal actuator and this
parameter is always positive.(Unit: unit/second)
REAL Constant, D
Accelerati
on
Additional acceleration of terminal actuator and this
parameter is always positive.(Unit: unit/second2)
REAL
Constant, D
Decelerati
on
Additive deceleration of terminal actuator and this
parameter is always positive.(Unit: unit/second2)
REAL Constant, D
Done
When the execution of MC_MoveSuperImposed is
completed, "Done" turns on; when “Execute” is off, "Done"
is reset.
BOOL M,Q
Abort
When this instruction execution is aborted, "Abort" turns
on; when “Execute” is off, "Abort" is reset.
BOOL M,Q
Busy
When the instruction execution is aborted, "Busy" turns on;
when “Done” is on or “Execute” is off, “Busy” is reset.
BOOL M,Q
Error
If any error is detected, "Error" turns on; when “Execute” is
off, "Error" is reset.
BOOL M,Q
Page view 62
1 2 ... 58 59 60 61 62 63 64 65 66 67 68 ... 338 339

Comments to this Manuals