4. Motion Control Instructions
DVP-MC operating manual 4-201
4.8.5.3 DNC_MOV(G0)Rapid positioning instruction
API
Controller
263
DNC_MOV(G0)
Rapid positioning instruction
10MC11T
Instruction explanation:
The instruction is used to do the rapid positioning of the servo axis in the specified group and control each
axis to move from current position to the terminal position at the specified speed. In motion, each axis is
independent with each other. The instruction is similar to G0 in function.
Explanation of input and output parameter of the instruction:
Parameter
name
Explanation
Data
type
Available
device
Execute
This instruction is executed when “Execute”
turns Off ->On.
BOOL M, I, Q, constant
X_Pos The terminal position of axis X, unit: unit. REAL Constant, D
Y_Pos The terminal position of axis Y, unit: unit. REAL Constant, D
Z_Pos The terminal position of axis Z, unit: unit. REAL Constant, D
A_Pos The terminal position of axis A, unit: unit. REAL Constant, D
B_Pos The terminal position of axis B, unit: unit. REAL Constant, D
C_Pos The terminal position of axis C, unit: unit. REAL Constant, D
P_Pos The terminal position of axis P, unit: unit. REAL Constant, D
Q_Pos The terminal position of axis Q, unit: unit. REAL Constant, D
GroupID
The number of the coordinate motion instruction
group, range: 0~7.
When the instruction is executed, the group ID
should be consistent with that of DNC_Group.
UINT Constant, D
Done
When parameter setting is finished, “Done” is on;
when “Execute” is off, “Done” is reset.
BOOL M,Q
Error
If any error is detected, "Error" turns on; when
"Execute" turns off, "Error" is reset.
BOOL M,Q
ErrorID Error code. Please refer to section 5.3. UINT D