DVP-MC operating manual A-15
Device name Device no. Type Addresshex
D 9984~9999 Word A700~A70F
Modbus Function code
The function code and abnormality response code when COM2 port is possessed by motion control module
are listed in the following table.
Function code Explanation
Available
device
0x02
Read bit-device register value; the data of 256 bits at most can be read
one time.
M,I,Q
0x03
Read one single or multi word register value; the data of 64 words at
most can be read one time.
D
0x05 Write one single bit-device register value. M ,Q
0x06 Write one single word-device register value. D
0x0F
Write multi bit-device register value; the data of 256 bits at most can be
written one time.
M,Q
0x10
Write multi word-device register value; the data of 64 words at most
can be written one time.
D
Abnormality
response code
Explanation
0x01 Unsupportive function code
0x02 Unsupportive Modbus address
0x03 The data length is out of the valid range.
The function code and abnormality response code when COM1 and COM2 ports are
possessed by PLC module in DVP10MC11T are listed in the following table.
Function code Explanation Available device
0x01
Read bit-device register value excluding the input
point state
S, Y, M, T, C
0x02
Read the bit-device register value including the input
point state
S, X, Y, M,T, C
0x03 Read one single or multi word device register value T, C, D
0x05 Write one single bit-device register value S, Y, M, T, C
0x06 Write one single word-device register value T, C, D
0x0F Write multi bit-device register value S, Y, M, T, C
0x10 Write multi word-device register value T, C, D