Delta D25886 User Manual Page 302

  • Download
  • Add to my manuals
  • Print
  • Page
    / 339
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 301
Appendix C
C-2 DVP-MC operating manual
Special
D
Modbus
address
HEX
Function explanation Range Type Latched Attribute
D24606 E01E
Axis current statesee
section 4.2
UINT No Read only
D24613 E025 -- No Read only
D24614 E026
The pulse number needed
when servo motor rotates
for one circle)
--
DINT
No Read only
D24615 E027
The allowed error between
the given and feedback
pulse number
-- UINT No Read only
D24619 E02B
Current torque (Rated
torque permillage)
-- INT No Read only
D24620 E02C -- No Read only
D24621 E02D
Current speed Unit: 0.1
r/min
DINT
No Read only
D24622 E02E
Present currentRated
current permillage
-- INT No Read only
D24623 E02F -- No Read only
D24624 E030
Custom parameter value
--
DINT
No Read only
D24625 E031
D24626 E032
The phase of the terminal
actuator
0~modulo REAL No Read only
D24627 E033
D24628 E034
The position of the terminal
actuator
-2147483648
~
2147483647
DINT No Read only
Note: The axis parameters such as Position, Velocity, Torque, Current and User defines parameter
can be read via special D only when they are selected. For the method of selecting the
relevant parameter, see section 2.3.1.